Case report 4 – Forme Fruste Keratoconus / High astigmatism / Irregular astigmatism
- 39yo male – American football player
- Forme Fruste K (pachs 498 um)
- OD: +4.75 / -3.00 x 1 (6/6-)
- 7.90/14.50/+4.25 medium skirt (6/6-)
- OS: +4.75 / -4.00 x 178 (6/6-)
- 7.90/14.50/+3.25 medium skirt (6/6-)
For information on the SynergEyes family of contact lenses and insertion and removal have a look here:SynergEyes Contact Lenses @ Mark Hinds Optometrists